IEC Certifications
Mining : Ex ib I Mb
Gas : Ex ib IIC T4 Gb
Dust : Ex ib IIIC T110°C Db
–20°C≤Ta≤+55°C
IEC 60079-0 (2011), IEC 60079-11 (2011)
IECEx/ATEX Intrinsically Safe Radio
IC-F3202DEX
Mining : I M2 Ex ib I Mb
Gas: II 2G Ex ib IIC T4 Gb
Dust: II 2D Ex ib IIIC T110°C Db
ATEX Certifications
Mining : I M2 Ex ib I Mb
Gas : II 2G Ex ib IIC T4 Gb
Dust : II 2D Ex ib IIIC T110°C Db
–20°C≤Ta≤+55°C
EN 60079-0 (2012), EN 60079-11 (2012)
IP67 Dust-tight & Waterproof Protection
The IC-F3202DEX series provides rugged protection against dust and
water that is equivalent to IP67. The IC-F3202DEX/F3203DEX series can withstand
1m depth of water for 30 minutes and its dust-tight construction shuts out
powder dust, sand and other objects.
IDAS™ Digital Mode Operation
The IC-F3202DEX series provides can program NXDN™ Type-D
single-site trunking and digital conventional as well as analog mode per channel.
The following digital features are programmable.
• PTT ID (TX) • Individual/Group calls • Block decode
• Radio check (RX) • Stun/kill/revive (RX) • Call alert (RX)
• Remote monitor (RX) • Emergency (TX) • Digital voice scrambler (15-bit)
• Power ON/OF
Analogue Mode Compatible
The IC-F3202DEX series has built-in 5-Tone, 2-Tone, CTCSS and
DTCS signaling capability for analogue mode group communication and selective
calling. The lone worker and man down functions automatically send an emergency
signal to assist in worker safety. The radio is perfect for use as an analogue
transceiver ready for future digital migration.
Frequency Range | 136–174MHz |
Number of Channels | 16 Channels |
Operating Temperature Range | -20°C to +55°C |
Dimensions | 63 × 144 × 50 mm |
Weight | 466gr |
RF Output Power | 1W |
Receiver Sensitivity | Digital: –9 dBμV emf typ. Analog: –5 dBμV emf typ. |
Audio Output Power | 400 mW typ. (at 5% distortion with 32 Ω load) |
Water & Dust Protection | IP67 (Dust and waterproof) |
Durability Standard | MIL-STD 810G |